GUL2.5 Intrinsically Safe Water Level Sensor for Mine
The intrinsically safe flow sensor can be used to monitor the water level, flow rate and flow capacity of roadways in mining areas. When the readings of the water level, flow rate and flow capacity exceed the set warning values or alarm values, alarm messages will be sent. The sensor can also be linked with drainage pumps through protocol docking.
Product overview
The intrinsically safe flow sensor can be used to monitor the water level, flow rate and flow capacity of roadways in mining areas. When the readings of the water level, flow rate and flow capacity exceed the set warning values or alarm values, alarm messages will be sent. The sensor can also be linked with drainage pumps through protocol docking.
Product parameters
Rated operating voltage: 8~24V.DC
Operating current: ≤80mA (12V.DC)
Standby current: ≤1mA (12V.DC)
Receiving sensitivity: ≥-130dBm
Transmission power: ≤20dBm
Radar frequency: 24GHZ
Lightning protection level: 2KV
Transmission mode: RS485 transmission
Protection class: IP68
copyright© 2026 Shenzhen Yiri Technology Co., Ltd.