Gas Sensor

The environmental sensor has a modular structure, in which gas detection probes can be configured as needed in the on-site environment. The body of the rail-mounted robot is equipped with CO, O2, CH4, H2S and other gas sensors.

Product overview

The environmental sensor has a modular structure, in which gas detection probes can be configured as needed in the on-site environment. The body of the rail-mounted robot is equipped with CO, O2, CH4, H2S and other gas sensors.

 

Product parameters

Gases to be detected: CO, CH4, O2, H2S

CO

Measurement range: 0-1000 ppm

Error: < reading ±3% (25℃)

Response time: <15S

Power consumption: ≤0.15W (@12V DC, 25℃)

CH4

Measurement range: 0-100%LEL

Error: 3%F.s

Response time: <15S

Power consumption: ≤1.5W (@12V DC, 25℃)

H2S

Measurement range: 0-100 ppm

Error: 3%F.s

Response time: <30S

Power consumption: ≤0.15W (@12V DC, 25℃)

O2

Measurement range: 0-1000 ppm

Error: < reading ±3% (25℃)

Response time: <15S

Power consumption: ≤0.15W (@12V DC, 25℃)